PP7553

|‌ PP-025-RBG14-QFPKG/US/ /V

Pressure sensors

Made in Germany
DrawingWiring PDF data sheet   Print Version

Collapse all categories
1: ventilation
2: sealing FPM / DIN 3869-14
Made in Germany
Product characteristics
Electronic pressure sensor
Quick disconnect
Communication interface: IO-Link 1.0
(COM2 slave, 38.4 kBaud)
Adjustment of the switch point by teach function
Process connection: G¼ male / M5 female
2 outputs
OUT1 = switching output
OUT2 = switching output or diagnostic output
Measuring range: 0...25 bar / 0...363 psi / 0...2.5 MPa
Application
Application Type of pressure: relative pressure
Liquids and gases
Pressure rating 150 bar2175 psi15 MPa
Bursting pressure min. 350 bar5075 psi35 MPa
Medium temperature [°C]-25...90
Electrical data
Electrical design DC PNP
Operating voltage [V]9.6...36 DC ¹)
Current consumption [mA]< 45
Insulation resistance [MΩ]> 100 (500 V DC)
Protection class III
Reverse polarity protection yes
Outputs
Output 2 outputs
OUT1 = switching output
OUT2 = switching output or diagnostic output
Output function 2 x normally open / closed programmable or 1 x normally open / closed programmable + 1 x normally closed (diagnostic function)
Current rating [mA]2 x 250
Voltage drop [V]< 2
Short-circuit protection Yes (non-latching)
Overload protection yes
Switching frequency [Hz]170
Measuring / setting range
Measuring range 0...25 bar0...363 psi0...2.5 MPa
Setting range
Set point, SP 0.2...25.0 bar4...362 psi0.02...2.50 MPa
Reset point, rP 0.1...24.9 bar2...360 psi0.01...2.49 MPa
in steps of 0.1 bar2 psi0.01 MPa
Factory setting SP1 = 6.3 bar; rP1 = 5.8 bar
SP2 = 18.8 bar; rP2 = 18.3 bar
OUT1 = Hno; OUT2 = Hno
Accuracy / deviations
Accuracy / deviations
(in % of the span)
Switch point accuracy < ± 0.5
Characteristics deviation *) < ± 0.25 (BFSL) / < ± 0.5 (LS)
Hysteresis < ± 0.1
Repeatability **) < ± 0.1
Long-term stability ***) < ± 0.1
Temperature coefficients (TEMPCO) in the temperature range 0...80° C (in % of the span per 10 K)
Greatest TEMPCO of the zero point 0.2
Greatest TEMPCO of the span 0.2
Reaction times
Power-on delay time [s]0.3
Min. response time switching output [ms]3
Damping for the switching output (dAP) [s]0.003 - 0.006 - 0.010 - 0.017 - 0.060 - 0.125 - 0.250 - 0.500
Interfaces
IO-Link Device
Transfer type COM2 (38.4 kBaud)
IO-Link revision 1.0
IO-Link Device ID 5 d / 00 00 05 h
Profiles no profile
SIO mode yes
Required master port class A
Process data analogue 1
Process data binary 2
Min. process cycle time [ms]2.3
Environment
Ambient temperature [°C]-25...85
Storage temperature [°C]-40...100
Protection IP 68 ****) / IP 69K
Tests / approvals
EMC
noise immunity  according to EN 61000-6-2
EN 61000-4-2 ESD:  4 kV contact discharge / 15 kV air discharge
EN 61000-4-3 HF radiated:  20 V/m
EN 61000-4-4 Burst:  4 kV coupling clamp
EN 61000-4-5 Surge:  0.5 kV supply / 1 kV signal for DC units
EN 61000-4-6 HF conducted:  10 V
noise immunity  according to the automotive directive 95/54/EC / 04/104EC / 05/83/EC
Absorber chamber test to ISO 11452-2:  80 V/m
EN 50155:  class T3, C1, S1
Shock resistance
DIN IEC 60068-2-27 / DIN IEC 60068-2-29: 1000 g  
DIN EN 61373: Category 3  
Vibration resistance
DIN IEC 68-2-6: 20 g (10...2000 Hz)  
DIN EN 60068-2-64: 14 g  
DIN EN 61373: Category 2  
MTTF [Years]310
Mechanical data
Process connection G¼ male / M5 female
Materials (wetted parts) stainless steel (303S22); ceramics; FPM (Viton)
Housing materials stainless steel (304S15); FPM (Viton); EPDM/X (Santoprene); PA
Switching cycles min. 100 million
Weight [kg]0.226
Displays / operating elements
Display
Power  2 x LED green
Switching status  2 x LED yellow
Electrical connection
Connection M12 connector
Wiring

----------OUT1/Teach/Data----------
data channel for bidirectional communication
in addition:
switching signal for pressure limit value or
input for teach signal
----------OUT2----------
switching signal for pressure limit value or
diagnostic signal
Remarks
Remarks
¹) supply voltage for communication mode: 18...32 V DC
referring to UL: “limited voltage” with overcurrent protection in accordance with UL508
*) BFSL = Best Fit Straight Line / LS = Limit Value Setting
**) with temperature fluctuations < 10 K
***) in % of the span per year
****) 7 days / 1 m water depth / 0.1 bar
e1 approval on request
Pack quantity [piece]1
ifm efector, inc. 782 Springdale Drive, Exton, PA 19341  —  We reserve the right to make technical alterations without prior notice.  —  US  —  PP7553  —  30.10.2013
 
up | Select language | PDF data sheet | Print Version
Approvals, classifications as well as product news, animations and videos on this product