PP7550

|‌ PP-400-SBG14-QFPKG/US/ /V

Pressure sensors

Made in Germany
DrawingWiring PDF data sheet   Print Version

Collapse all categories
1: Pressure relief mechanism
No mechanical force must be exerted on the pressure relief mechanism.
2: sealing FPM / DIN 3869-14
Made in Germany
Product characteristics
Electronic pressure sensor
Quick disconnect
Communication interface: IO-Link 1.0
(COM2 slave, 38.4 kBaud)
Adjustment of the switch point by teach function
Process connection: G¼ male / M5 female
2 outputs
OUT1 = switching output
OUT2 = switching output or diagnostic output
Measuring range: 0...400 bar / 0...5800 psi / 0...40 MPa
Application
Application Type of pressure: relative pressure
Liquids and gases
Use in gases at pressures > 25 bar only after contacting the manufacturer ifm
Pressure rating 600 bar8700 psi60 MPa
Bursting pressure min. 1000 bar14500 psi100 MPa
Medium temperature [°C]-25...90
Electrical data
Electrical design DC PNP
Operating voltage [V]9.6...36 DC ¹)
Current consumption [mA]< 45
Insulation resistance [MΩ]> 100 (500 V DC)
Protection class III
Reverse polarity protection yes
Outputs
Output 2 outputs
OUT1 = switching output
OUT2 = switching output or diagnostic output
Output function 2 x normally open / closed programmable or 1 x normally open / closed programmable + 1 x normally closed (diagnostic function)
Current rating [mA]2 x 250
Voltage drop [V]< 2
Short-circuit protection Yes (non-latching)
Overload protection yes
Switching frequency [Hz]170
Measuring / setting range
Measuring range 0...400 bar0...5800 psi0...40 MPa
Setting range
Set point, SP 4...400 bar60...5790 psi0.4...40.0 MPa
Reset point, rP 2...398 bar30...5760 psi0.2...39.8 MPa
in steps of 2 bar30 psi0.2 MPa
Factory setting SP1 = 100 bar; rP1 = 92 bar
SP2 = 300 bar; rP2 = 292 bar
OUT1 = Hno; OUT2 = Hno
Accuracy / deviations
Accuracy / deviations
(in % of the span)
Switch point accuracy < ± 0.5
Characteristics deviation *) < ± 0.25 (BFSL) / < ± 0.5 (LS)
Hysteresis < ± 0.1
Repeatability **) < ± 0.1
Long-term stability ***) < ± 0.1
Temperature coefficients (TEMPCO) in the temperature range 0...80° C (in % of the span per 10 K)
Greatest TEMPCO of the zero point 0.2
Greatest TEMPCO of the span 0.2
Reaction times
Power-on delay time [s]0.3
Min. response time switching output [ms]3
Damping for the switching output (dAP) [s]0.003 - 0.006 - 0.010 - 0.017 - 0.060 - 0.125 - 0.250 - 0.500
Interfaces
IO-Link Device
Transfer type COM2 (38.4 kBaud)
IO-Link revision 1.0
IO-Link Device ID 2 d / 00 00 02 h
Profiles no profile
SIO mode yes
Required master port class A
Process data analogue 1
Process data binary 2
Min. process cycle time [ms]2.3
Environment
Ambient temperature [°C]-25...85
Storage temperature [°C]-40...100
Protection IP 68 ****) / IP 69K
Tests / approvals
EMC
noise immunity  according to EN 61000-6-2
EN 61000-4-2 ESD:  4 kV contact discharge / 15 kV air discharge
EN 61000-4-3 HF radiated:  20 V/m (80...1000 MHz)
EN 61000-4-4 Burst:  4 kV coupling clamp
EN 61000-4-5 Surge:  0.5 kV supply / 1 kV signal for DC units
EN 61000-4-6 HF conducted:  10 V (0.15...80 MHz)
noise immunity  according to the automotive directive 95/54/EC / 04/104EC / 05/83/EC
Absorber chamber test to ISO 11452-2:  80 V/m (20...2000 MHz)
EN 50155:  class T3, C1, S1
Shock resistance
DIN IEC 60068-2-27 / DIN IEC 60068-2-29: 1000 g  
DIN EN 61373: Category 3  
Vibration resistance
DIN IEC 68-2-6: 20 g (10...2000 Hz)  
DIN EN 60068-2-64: 14 g  
DIN EN 61373: Category 2  
MTTF [Years]310
Mechanical data
Process connection G¼ male / M5 female
Materials (wetted parts) stainless steel (303S22); ceramics; FPM (Viton)
Housing materials stainless steel (304S15); FPM (Viton); EPDM/X (Santoprene); PA
Switching cycles min. 100 million
Weight [kg]0.22
Displays / operating elements
Display
Power  2 x LED green
Switching status  2 x LED yellow
Electrical connection
Connection M12 connector
Wiring

----------OUT1/Teach/Data----------
data channel for bidirectional communication
in addition:
switching signal for pressure limit value or
input for teach signal
----------OUT2----------
switching signal for pressure limit value or
diagnostic signal
Remarks
Remarks
¹) supply voltage for communication mode: 18...32 V DC
*) BFSL = Best Fit Straight Line / LS = Limit Value Setting
**) with temperature fluctuations < 10 K
***) in % of the span per year
****) 7 days / 1 m water depth / 0.1 bar
e1 approval on request
Pack quantity [piece]1
ifm efector, inc. 782 Springdale Drive, Exton, PA 19341  —  We reserve the right to make technical alterations without prior notice.  —  US  —  PP7550  —  30.10.2013
 
up | Select language | PDF data sheet | Print Version
Approvals, classifications as well as product news, animations and videos on this product