O1D100

|· O1DLF3KG/IO-LINK

Photoelectric sensors

DrawingWiring3D PDF PDF data sheet   Print Version

Collapse all categories
1: 4-digit alphanumeric display
2: Programming buttons
Product characteristics
Photoelectric distance sensor
Quick disconnect
Background suppression
Visible laser light, protection class 2 laser
4-digit alphanumeric display
Measuring range 0.2...10 m (Range referred to white paper 200 x 200 mm, 90 % remission)
Background suppression 0...19 m
Electrical data
Electrical design DC PNP
Operating voltage [V]18...30 DC
Current consumption [mA]< 150
Life expectancy typ. [h]50000
Protection class III
Reverse polarity protection yes
Outputs
Output function OUT1: normally open / closed programmable
OUT2: normally open / closed programmable or analog (4...20 mA / 0...10 V, scalable)
Current rating [mA]2 x 200
Short-circuit protection yes (non-latching)
Overload protection yes
Analog output
current output [mA]4...20; according to IEC 61131-2
- Max. load [Ω]250
voltage output [V]0...10; according to IEC 61131-2
- Min. load [Ω]5000
Monitoring range
Background suppression 0...19 m
Light spot diameter [mm]< 15 x 15 ( Range 10 m )
Measuring / setting range
Measuring range [m]0.2...10 (Range referred to white paper 200 x 200 mm, 90 % remission)
Sampling rate [Hz]1...50
Interfaces
IO-Link Device
Transfer type COM (38.4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
IO-Link Device ID 806d / 00 03 26h
Profiles Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis
SIO mode yes
Required master port class A
Process data analogue 2
Process data binary 3
Min. process cycle time [ms]6.0
Environment
Ambient temperature [°C]-10...60
Protection IP 67
Tests / approvals
EMC EN 60947-5-2
MTTF [Years]186
Mechanical data
Housing materials housing: diecast zinc; window: glass; LED window: polycarbonate
Weight [kg]0.291
Displays / operating elements
Display
Switching status  2 x LED yellow
Power  LED green
Distance, programming  4-digit alphanumeric display
Electrical connection
Connection M12 connector
Wiring
Accessories
Accessories (optional)
Protective cover E21133
Remarks
Remarks
Achtung: Laserlicht
Leistung <= 4.1 mW Wellenlänge 650 nm
Puls 1.3 ns
Nicht in den Strahl blicken
Kontakt mit Laserlicht vermeiden
LASER KLASSE 2
EN 60825-1:2007-10
cULus - Class 2 source required
Pack quantity [piece]1
Other data

Parameter Setting range Factory setting
Uni mm, m, inch mm
OU1 Hno, Hnc, Fno, Fnc Hno
SP1 [mm] 200...9999 1000
nSP1 [mm] 200...9999 800
FSP1 [mm] 200...9999 1200
OU2 Hno, Hnc, Fno, Fnc, I, U I
SP2 [mm] 200...9999 2000
nSP2 [mm] 200...9999 1800
FSP2 [mm] 200...9999 2200
ASP [mm] 0...9999 0
AEP [mm] 0...9999 9999
rATE [Hz] 1...50 50
dS1 [s] 0...0.1...5 0
dr1 [s] 0...0.1...5 0
dS2 [s] 0...0.1...5 0
dr2 [s] 0...0.1...5 0
dFo [s] 0...0.1...5 0
dIS d1..3; rd1...3; OFF d3

Repeatability / Accuracy
Sampling rate 50 Hz  - extraneous light on the object max.: 40 klx
Repeatability of the measured values Accuracy
white (90 % remission) grey (18 % remission) white (90 % remission) grey (18 % remission)
200...1000 mm ± 5.0 mm ± 7.5 mm ± 15.0 mm ± 18.0 mm
1000...2000 mm ± 5.5 mm ± 10.0 mm ± 15.0 mm ± 20.0 mm
2000...4000 mm ± 17.5 mm ± 22.5 mm ± 25.0 mm ± 32.0 mm
4000...6000 mm ± 27.5 mm ± 40.0 mm ± 35.0 mm ± 50.0 mm
6000...10000 mm ± 60.0 mm -- ± 70.0 mm --

Repeatability / Accuracy
Sampling rate 50 Hz  - extraneous light on the object max.: 40...100 klx
Repeatability of the measured values Accuracy
white (90 % remission) grey (18 % remission) white (90 % remission) grey (18 % remission)
200...1000 mm ± 16.5 mm ± 16.5 mm ± 26.5 mm ± 26.5 mm
1000...2000 mm ± 16.5 mm ± 16.5 mm ± 26.5 mm ± 26.5 mm
2000...4000 mm ± 30.0 mm ± 37.0 mm ± 40.0 mm ± 47.0 mm
4000...6000 mm ± 37.0 mm ± 57.0 mm ± 47.0 mm ± 67.0 mm
6000...10000 mm ± 75.0 mm -- ± 85.0 mm --

Repeatability / Accuracy
Sampling rate 1 Hz  - extraneous light on the object max.: 40 klx
Repeatability of the measured values Accuracy
white (90 % remission) grey (18 % remission) white (90 % remission) grey (18 % remission)
200...1000 mm ± 4.0 mm ± 4.5 mm ± 14.0 mm ± 15.0 mm
1000...2000 mm ± 4.5 mm ± 6.0 mm ± 14.5 mm ± 16.0 mm
2000...4000 mm ± 13.5 mm ± 14.5 mm ± 23.5 mm ± 24.0 mm
4000...6000 mm ± 19.0 mm ± 21.0 mm ± 29.0 mm ± 31.0 mm
6000...10000 mm ± 37.0 mm -- ± 47.0 mm --

Repeatability / Accuracy
Sampling rate 1 Hz  - extraneous light on the object max.: 40...100 klx
Repeatability of the measured values Accuracy
white (90 % remission) grey (18 % remission) white (90 % remission) grey (18 % remission)
200...1000 mm ± 10.0 mm ± 10.0 mm ± 20.0 mm ± 20.0 mm
1000...2000 mm ± 10.0 mm ± 10.0 mm ± 20.0 mm ± 20.0 mm
2000...4000 mm ± 17.0 mm ± 18.0 mm ± 27.0 mm ± 28.0 mm
4000...6000 mm ± 22.0 mm ± 25.0 mm ± 32.0 mm ± 35.0 mm
6000...10000 mm ± 37.0 mm -- ± 47.0 mm --

Range on black (6 % remission) <= 4000 mm
The values apply at
- constant ambient conditions: 23 °C / 960 hPa
- minimum power-on time in minutes: 10



ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355  —  We reserve the right to make technical alterations without prior notice.  —  US  —  O1D100  —  28.09.2017
 
up | Select language | PDF data sheet | Print Version
Approvals, classifications as well as product news, animations and videos on this product