Number of inputs and outputs | Number of digital outputs: 1; Number of analog outputs: 1 |
---|---|
Process connection | threaded connection M16 x 2 external thread Minimess |
Media | mineral oils (e.g. HLP); ester oils (e.g. HEES); biodegradable oils (e.g. HETG) |
---|
Medium temperature [°C] | -10...80 |
---|
Operating voltage [V] | 9...33 DC |
---|---|
Current consumption [mA] | 9...50 |
Protection class | III |
Measuring principle | photoelectric |
Number of inputs and outputs | Number of digital outputs: 1; Number of analog outputs: 1 |
---|
Total number of outputs | 2 |
---|---|
Number of digital outputs | 1 |
Permanent current rating of switching output DC [mA] | 500 |
Number of analog outputs | 1 |
Analog current output [mA] | 4...20 |
Max. load [Ω] | (Ub - 4 V) / 20 mA; Ub = 24 V: 1000 |
Short-circuit proof | no |
Overload protection | no |
Measuring range | 10...22; (Range number) |
---|---|
Display range | 0...24; (Range number) |
Accuracy | ± 1; (Range number) |
---|
Parameter setting options | via buttons, PC or digital I/O |
---|
Communication interface | CAN |
---|
Ambient temperature [°C] | -10...60 |
---|---|
Storage temperature [°C] | -20...60 |
Protection | IP 67 |
MTTF [years] | 129 |
---|---|
Pressure equipment directive | article 3, section 3 - sound engineering practice |
Weight [g] | 829 |
---|---|
Materials (wetted parts) | stainless steel (1.4028 / 420); sapphire; NBR; chromium |
Process connection | threaded connection M16 x 2 external thread Minimess |
Display |
|
---|
Pack quantity | 1 pcs. |
---|
Connection | Connector: 1 x M12; coding: A |
---|