PI2692

|‌ PI-100-REA01-MFRKG/US/ /P

Pressure sensors

Made in Germany
DrawingWiring3D PDF PDF data sheet   Print Version


5 Years Warranty
Collapse all categories
1: 4-digit alphanumeric display
2: LEDs
3: Programming button
Made in Germany
Product characteristics
Combined pressure sensor
Connector
no dead space
Freely rotatable housing 350°
Zero and span adjustable
Display units:
bar, psi, MPa, % of the span
Function programmable
Sealing cone G1 male
Process connection: Sealing cone G1 male
2 outputs
OUT1 = switching output
OUT2 = analogue output
4-digit alphanumeric display
Measuring range: -1.0...100.0 bar / -15...1450 psi / -0.10...10.00 MPa
Application
Application Type of pressure: relative pressure
Hygienic systems, viscous media and liquids with suspended particles
Liquids and gases
Use in gases at pressures > 25 bar only after contacting the manufacturer ifm
Pressure rating 200 bar2900 psi20 MPa
Bursting pressure min. 650 bar9425 psi65 MPa
Medium temperature [°C]-25...125 (145 max. 1h)
Electrical data
Electrical design DC PNP/NPN
Operating voltage [V]18...32 DC
Current consumption [mA]< 50
Insulation resistance [MΩ]> 100 (500 V DC)
Protection class III
Reverse polarity protection yes
Outputs
Output 2 outputs
OUT1 = switching output
OUT2 = analogue output
Output function 1 x normally open / closed programmable + 1 x analogue (I / U, scaleable 1:4)
Current rating [mA]250
Voltage drop [V]< 2
Short-circuit protection pulsed
Overload protection yes
Switching frequency [Hz]6
Analogue output I: 4...20 mA (Ineg: 20...4 mA) / U: 0...10 V (Uneg: 10...0 V)
Max. load [Ω]I / Ineg: max. (Ub - 10 V) x 50; U / Uneg: min. 2000
Measuring / setting range
Measuring range -1.0...100.0 bar-15...1450 psi-0.10...10.00 MPa
Setting range
Set point, SP -0.8...100.0 bar -13...1450 psi -0.08...10.00 MPa
Reset point, rP -1.0...99.8 bar -15...1448 psi -0.10...9.98 MPa
Analogue start point, ASP -1.0...75.0 bar -15...1088 psi -0.10...7.50 MPa
Analogue end point, AEP 24.0...100.0 bar 348...1450 psi 2.40...10.00 MPa
in steps of 0.1 bar 1 psi 0.01 MPa
Factory setting SP1 = 25.0 bar; rP1 = 23.0 bar
ASP = 0.0 bar; AEP = 100.0 bar
Accuracy / deviations
Accuracy / deviations
(in % of the span) Turn down 1:1
Switch point accuracy < ± 0.2
Characteristics deviation *) < ± 0.2
Linearity < ± 0.15
Hysteresis < ± 0.15
Repeatability **) < ± 0.1
Long-term stability ***) < ± 0.1
Temperature coefficients (TEMPCO) in the temperature range 0...70° C (in % of the span per 10 K)
Greatest TEMPCO of the zero point < ± 0.05
Greatest TEMPCO of the span < ± 0.15
Reaction times
Power-on delay time [s]0.5
Min. response time switching output [ms]100
Damping for the switching output (dAP) [s]0.1...100.0
Damping for the analogue output (dAA) [s]0.1...100.0
Step response time analogue output [ms]25
Integrated watchdog yes
Software / programming
Programming options hysteresis / window function; N.O. / N.C; output polarity; current / voltage outputs; damping; calibration of displayed values; display can be rotated / deactivated; display unit
Environment
Ambient temperature [°C]-25...80
Storage temperature [°C]-40...100
Protection IP 67 / IP 69K
Tests / approvals
EMC
EN 61000-4-2 ESD:  4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated:  10 V/m
EN 61000-4-4 Burst:  2 kV
EN 61000-4-5 Surge:  0.5/1 kV
EN 61000-4-6 HF conducted:  10 V
Shock resistance
DIN IEC 68-2-27: 50 g (11 ms)  
Vibration resistance
DIN IEC 68-2-6: 20 g (10...2000 Hz)  
MTTF [Years]163
Mechanical data
Process connection Sealing cone G1 male
Materials (wetted parts) ceramics; PTFE; stainless steel 316L / 1.4435; surface characteristics: Ra < 0.4 / Rz 4
Housing materials stainless steel 316L / 1.4404; PC (Makrolon); PBT (Pocan); PEI; FPM (Viton); PTFE
Switching cycles min. 100 million
Weight [kg]0.452
Displays / operating elements
Display
Display unit  4 x LED green
Switching status  LED yellow
Function display  4-digit alphanumeric display
Measured values  4-digit alphanumeric display
Electrical connection
Connection M12 connector; Gold-plated contacts
Wiring

Programming of the output function
----------OUT1----------
- Switching output
Hno = hysteresis / normally open
Hnc = hysteresis / normally closed
Fno = window function / normally
open
Fnc = window function / normally
closed
----------OUT2----------
- Analogue output
I = current output (4...20 mA)
U = voltage output (0...10 V)
Remarks
Remarks
*) linearity, incl. hysteresis and repeatability;
(limit value setting to DIN 16086)
**) with temperature fluctuations < 10 K
***) in % of the span per year
The 3-A qualification is only valid if adapters with 3-A qualification are used for installation.
Pack quantity [piece]1
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen  —  We reserve the right to make technical alterations without prior notice.  —  GB  —  PI2692  —  21.11.2012
 
up | Select language | PDF data sheet | Print Version
Approvals, classifications as well as product news, animations and videos on this product