PN7001

|‌ PN-250-SBR14-QFRKG/US/ /V

Pressure sensors

Made in Germany
DrawingWiring3D PDF PDF data sheet   Print Version

Collapse all categories
1: 4-digit alphanumeric display
2: LEDs (display unit / switching status)
3: Programming button
Made in Germany
Product characteristics
Electronic pressure monitor
M12 connector
Communication interface: IO-Link 1.1 (COM2 slave, 38.4 kBaud)
Function programmable
Process connection: G ¼ I
2 outputs
OUT1 = switching output
OUT2 = switching output or diagnostic output
4-digit alphanumeric display
Measuring range: 0...250 bar / 0...3625 psi / 0...25 MPa
Application
Application Type of pressure: relative pressure
Liquids and gases
Use in gases at pressures > 25 bar only after contacting the manufacturer ifm
Pressure rating 400 bar5800 psi40 MPa
Bursting pressure min. 850 bar12300 psi85 MPa
Medium temperature [°C]-25...80
Electrical data
Electrical design DC PNP/NPN
Operating voltage [V]18...36 DC ¹)
Current consumption [mA]< 35
Insulation resistance [MΩ]> 100 (500 V DC)
Protection class III
Reverse polarity protection yes
Overvoltage protection [V]up to 40
Outputs
Output 2 outputs
OUT1 = switching output
OUT2 = switching output or diagnostic output
Output function 2 x normally open / closed programmable or 1 x normally open / closed programmable + 1 x normally closed (diagnostic function)
Current rating [mA]250
Voltage drop [V]< 2
Short-circuit protection pulsed
Switching frequency [Hz]≤ 170
Measuring / setting range
Measuring range 0...250 bar0...3625 psi0...25 MPa
Setting range
Set point, SP 2...250 bar40...3620 psi0.2...25.0 MPa
Reset point, rP 1...249 bar20...3600 psi0.1...24.9 MPa
in steps of 1 bar20 psi0.1 MPa
Factory setting SP1 = 63 bar; rP1 = 58 bar
SP2 = 188 bar; rP2 = 183 bar
Accuracy / deviations
Accuracy / deviations
(in % of the span)
Switch point accuracy < ± 0.5
Characteristics deviation *) < ± 0.25 (BFSL) / < ± 0.5 (LS)
Hysteresis < ± 0.25
Repeatability **) < ± 0.1
Long-term stability ***) < ± 0.05
Temperature coefficients (TEMPCO) in the temperature range 0...80° C (in % of the span per 10 K)
Greatest TEMPCO of the zero point 0.2
Greatest TEMPCO of the span 0.2
Reaction times
Power-on delay time [s]0.3
Delay time programmable dS, dr [s]0; 0.2...50
Integrated watchdog yes
Software / programming
Programming options hysteresis / window function; N.O. / N.C; diagnostic function; output polarity; on delay, off delay; damping; display unit
Interfaces
IO-Link Device
Transfer type COM2 (38.4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9 CDV
IO-Link Device ID 308 d / 00 01 34 h
Profiles no profile
SIO mode yes
Required master port type A
Process data analogue 1
Process data binary 2
Min. process cycle time [ms]2.3
Environment
Ambient temperature [°C]-20...80 (UB < 32 V) / -20...60 (UB > 32 V)
Storage temperature [°C]-40...100
Protection IP 67
Tests / approvals
EMC
EN 61000-4-2 ESD:  4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated:  10 V/m
EN 61000-4-4 Burst:  2 kV
EN 61000-4-5 Surge:  0.5/1 kV
EN 61000-4-6 HF conducted:  10 V
Shock resistance
DIN IEC 68-2-27: 50 g (11 ms)  
Vibration resistance
DIN IEC 68-2-6: 20 g (10...2000 Hz)  
MTTF [Years]219
Mechanical data
Process connection G ¼ I
Materials (wetted parts) stainless steel (303S22); ceramics; FPM (Viton)
Housing materials stainless steel (304S15); stainless steel 316L / 1.4404; PC (Makrolon); PBT (Pocan); PEI; FPM (Viton)
Switching cycles min. 100 million
Weight [kg]0.263
Displays / operating elements
Display
Display unit  3 x LED green
Switching status  2 x LED yellow
Function display  4-digit alphanumeric display
Measured values  4-digit alphanumeric display
Electrical connection
Connection M12 connector; Gold-plated contacts
Wiring

Programming of the output function
----------OUT1----------
Hno = hysteresis / normally open
Hnc = hysteresis / normally closed
Fno = window function / normally
open
Fnc = window function / normally
closed
----------OUT2----------
Hno = hysteresis / normally open
Hnc = hysteresis / normally closed
Fno = window function / normally
open
Fnc = window function / normally
closed
dESI = diagnostic function (normally
closed)
Remarks
Remarks
¹) to EN50178, SELV, PELV
*) BFSL = Best Fit Straight Line / LS = Limit Value Setting
**) with temperature fluctuations < 10 K
***) in% of the span / 6 months
Pack quantity [piece]1
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen  —  We reserve the right to make technical alterations without prior notice.  —  GB  —  PN7001  —  30.10.2013
 
up | Select language | PDF data sheet | Print Version
Approvals, classifications as well as product news, animations and videos on this product