O1D100

|‌ O1DLF3KG

Photoelectric sensors

Made in Germany
DrawingWiring3D PDF PDF data sheet   Print Version

Collapse all categories
1: 4-digit alphanumeric display
2: Programming buttons
Made in Germany
Product characteristics
Photoelectric distance sensor
Connector
Visible laser light, protection class 2 laser
4-digit alphanumeric display
Measuring range 0.2...10 m (Range referred to white paper 200 x 200 mm, 90 % remission)
Application 0...19 m
Application
Application [m]0...19
Electrical data
Electrical design DC PNP
Operating voltage [V]18...30 DC *)
Current consumption [mA]< 150
Life expectancy typ. [h]50000
Protection class III
Reverse polarity protection yes
Outputs
Output function OUT1: normally open / closed programmable
OUT2: normally open / closed programmable or analogue (4...20 mA / 0...10 V, scalable)
Current rating [mA]2 x 200
Short-circuit protection pulsed
Overload protection yes
Analogue output
current output [mA]4...20; according to IEC 61131-2
- Max. load [Ω]250
voltage output [V]0...10; according to IEC 61131-2
- Min. load [Ω]5000
Range
Light spot diameter [mm]< 15 x 15 ( Range 10 m )
Measuring / setting range
Measuring range [m]0.2...10 (Range referred to white paper 200 x 200 mm, 90 % remission)
Sampling rate [Hz]1...50
Environment
Ambient temperature [°C]-10...60
Protection IP 67
Tests / approvals
EMC EN 60947-5-2
MTTF [Years]186
Mechanical data
Housing materials housing: diecast zinc; window: glass; LED window: polycarbonate
Weight [kg]0.291
Displays / operating elements
Display
Switching status  2 x LED yellow
Operation  LED green
Distance, programming  4-digit alphanumeric display
Electrical connection
Connection M12 connector
Wiring
Accessories
Accessories (optional)
Protective cover E21133
Remarks
Remarks
*) cULus - Class 2 source required
Caution: Laser Light
Power <= 4.1 mW wavelength = 650 nm
pulse 1.3 ns
Do not stare into beam
Avoid exposure
Class 2 laser product
EN 60825-1:2003-10
For more information about the measuring range / application please refer to the operating instructions.
Pack quantity [piece]1
Other data

Parameter Setting range Factory setting
Uni mm, m, inch mm
OU1 Hno, Hnc, Fno, Fnc Hno
SP1 200...9999 1000
nSP1 200...9999 800
FSP1 200...9999 1200
OU2 Hno, Hnc, Fno, Fnc, I, U I
SP2 200...9999 2000
nSP2 200...9999 1800
FSP2 200...9999 2200
ASP 0...9999 0
AEP 0...9999 9999
rATE [Hz] 1...50 50
dS1 0...0.1...5 0
dr1 0...0.1...5 0
dS2 0...0.1...5 0
dr2 0...0.1...5 0
dAP 0...0.1...5 0
dIS d1..3; rd1...3; OFF d3

Repeatability / Accuracy
Sampling rate 50 Hz  - extraneous light on the object max.: 40 klx
Repeatability of the measured values Accuracy
white (90 % remission) grey (18 % remission) white (90 % remission) grey (18 % remission)
200...1000 mm ± 5.0 mm ± 7.5 mm ± 15.0 mm ± 18.0 mm
1000...2000 mm ± 5.5 mm ± 10.0 mm ± 15.0 mm ± 20.0 mm
2000...4000 mm ± 17.5 mm ± 22.5 mm ± 25.0 mm ± 32.0 mm
4000...6000 mm ± 27.5 mm ± 40.0 mm ± 35.0 mm ± 50.0 mm
6000...10000 mm ± 60.0 mm -- ± 70.0 mm --

Repeatability / Accuracy
Sampling rate 50 Hz  - extraneous light on the object max.: 40...100 klx
Repeatability of the measured values Accuracy
white (90 % remission) grey (18 % remission) white (90 % remission) grey (18 % remission)
200...1000 mm ± 16.5 mm ± 16.5 mm ± 26.5 mm ± 26.5 mm
1000...2000 mm ± 16.5 mm ± 16.5 mm ± 26.5 mm ± 26.5 mm
2000...4000 mm ± 30.0 mm ± 37.0 mm ± 40.0 mm ± 47.0 mm
4000...6000 mm ± 37.0 mm ± 57.0 mm ± 47.0 mm ± 67.0 mm
6000...10000 mm ± 75.0 mm -- ± 85.0 mm --

Repeatability / Accuracy
Sampling rate 1 Hz  - extraneous light on the object max.: 40 klx
Repeatability of the measured values Accuracy
white (90 % remission) grey (18 % remission) white (90 % remission) grey (18 % remission)
200...1000 mm ± 4.0 mm ± 4.5 mm ± 14.0 mm ± 15.0 mm
1000...2000 mm ± 4.5 mm ± 6.0 mm ± 14.5 mm ± 16.0 mm
2000...4000 mm ± 13.5 mm ± 14.5 mm ± 23.5 mm ± 24.0 mm
4000...6000 mm ± 19.0 mm ± 21.0 mm ± 29.0 mm ± 31.0 mm
6000...10000 mm ± 37.0 mm -- ± 47.0 mm --

Repeatability / Accuracy
Sampling rate 1 Hz  - extraneous light on the object max.: 40...100 klx
Repeatability of the measured values Accuracy
white (90 % remission) grey (18 % remission) white (90 % remission) grey (18 % remission)
200...1000 mm ± 10.0 mm ± 10.0 mm ± 20.0 mm ± 20.0 mm
1000...2000 mm ± 10.0 mm ± 10.0 mm ± 20.0 mm ± 20.0 mm
2000...4000 mm ± 17.0 mm ± 18.0 mm ± 27.0 mm ± 28.0 mm
4000...6000 mm ± 22.0 mm ± 25.0 mm ± 32.0 mm ± 35.0 mm
6000...10000 mm ± 37.0 mm -- ± 47.0 mm --

Range on black (6 % remission) <= 4000 mm
The values apply at
- constant ambient conditions: 23 °C / 960 hPa
- minimum power-on time in minutes: 10



ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen  —  We reserve the right to make technical alterations without prior notice.  —  GB  —  O1D100  —  18.01.2011
 
up | Select language | PDF data sheet | Print Version
Approvals, classifications as well as product news, animations and videos on this product